logo

제품 세부 정보

Created with Pixso. Created with Pixso. 상품 Created with Pixso.
ESP 컨트롤러
Created with Pixso.

283-325V,9.1KW A06B-6096-H106 AC Servo Amplifier Fanuc ALPHA SERVO MODULE

283-325V,9.1KW A06B-6096-H106 AC Servo Amplifier Fanuc ALPHA SERVO MODULE

브랜드 이름: Fanuc
모델 번호: A06B-6096-H106
MOQ: 1
가격: Negotiations
자세한 정보
원래 장소:
일본
등급 입력:
283-325V
최대 출력 전압:
230V
정격 출력 전류:
52.2V
포장 세부 사항:
새로운 원본 상자
강조하다:

Fanuc ALPHA servo amplifier module

,

283-325V AC servo amplifier

,

9.1KW Fanuc servo module

제품 설명
283-325V,9.1KW A06B-6096-H106 AC Servo Amplifier Fanuc ALPHA SERVO MODULE
283-325V,9.1KW A06B-6096-H106 AC Servo Amplifier Fanuc ALPHA SERVO MODULE
Item Description
  • Manufacturer: Fanuc
  • Model #: A06B-6096-H106 or A06B6096H106
  • Category: Servo Amplifier
  • SERVO AMP MODULE
  • SVM1-130
  • Item Weight: 20 lbs.
Specifications
  • Rated Input: 283-325V
  • Maximum Output Voltage: 230V
  • Rated Output Current: 52.2V
  • Power: 9.1kW
Quick Details
Brand Fanuc
Country of Origin Japan
Part Number A06B-6096-H106
Type AC Servo Amplifier
Configuration Instructions
  1. Make NC PRM 960.3 (PMN) = 0 (Enables PMM function).
  2. Select where parameters are to be saved (to save to memory card on i series controls make PRM 960.2 (MD2) = 0 and PRM 960.1 (MD1) = 1, to save as a part program make PRM 960.1 = 0).
  3. Set parameter 8760 to the program number you want the parameters to be stored as. Note 1.
  4. Press the SYSTEM button then the RIGHT CHAPTER button until the Power Motion Manager screen is displayed.
  5. Press the SYSTEM soft key.
  6. Press the PARAM soft key.
  7. Press the OPRT soft key.
  8. Press the RIGHT CHAPTER button. READ and PUNCH soft keys will be displayed.
  9. Select EDIT mode.
  10. To save parameters from Beta drive to CNC press the READ soft key, press the ALL soft key then the EXEC soft key.
  11. To restore the parameters from the CNC to the Beta drive press the PUNCH soft key, press the ALL soft key then the EXEC soft key.
Parameter 960.0 (SLV) determines how many slaves are displayed on the screen when the Power Motion Manager is selected.
0 = One slave.
1 = Up to four slaves with the screen divided into four.
Parameters 960.1 (MD1) and 960.2 (MD2) set the slave parameter input/output destination.
MD1 = 0, MD2 = 0, destination is the part program storage.
MD1 = 1, MD2 = 0, destination is the memory card.
Parameter 960.3 (PMN) sets the status of the power motion manager function.
0 = Enabled
1 = Disabled (Communication with slaves is not performed).
Note 1: The program under which the parameters will be stored is derived by multiplying the number of the Fanuc Beta Drive I/O link group by 10 and adding the result to the value in parameter 8760. So if the group number is 2 and the value of parameter 8760 is 9000, then 9000 + (2 x 10) = 9020, the parameters will be stored in program O9020